Instruction Manual
Model 3016-2124
Downconverter
August 2012, Rev. 0
MENU
EXECUTE
MODEL 3016
CROSS TECHNOLOGIES INC.
REMOTE POWERALARM
DOWNCONVERTER
RF MONITOR
F=23123.125
G=+10 Ref = AUTO-I
Data, drawings, and other material contained herein are proprietary to Cross Technologies, Inc., but may be
reproduced or duplicated without the prior permission of Cross Technologies, Inc. for purposes of operating
the equipment.
When ordering parts from Cross Technologies, Inc., be sure to include the equipment model number,
equipment serial number, and a description of the part.
CROSS TECHNOLOGIES, INC.
6170 Shiloh Road
Alpharetta, Georgia 30005
(770) 886-8005
FAX (770) 886-7964
Toll Free 888-900-5588
WEB www.crosstechnologies.com
Page view 0
1 2 3 4 5 6 ... 16 17

Summary of Contents

Page 1 - Model 3016-2124

Instruction Manual Model 3016-2124 DownconverterAugust 2012, Rev. 0MENUEXECUTEMODEL 3016CROSS TECHNOLOGIES INC.REMOTE POW

Page 2

2.2 Rear Panel Input/Output Signals Figure 2.2 shows the input and output connectors on the rear panel.ACGNDJ1J10ANDMONITORCONTROL 5 4 3 2

Page 3 - MODEL 3016-2124-Downconverter

2.4 Operation2.4.1 Installing and Operating the 3016-2124 Downconverter1. Connect a -50 dBm to -30 dBm signal to RF IN, J2 (Figure 2.2, page 10).2.

Page 4 - -01

2.5 Menu Settings2.5.1 Functions This section describes operation of the front panel controls. There are three operator switches, the LCD displa

Page 5

2.5.2 Power On SettingsNOTE: THE LAST STATUS OF A UNIT IS RETAINED EVEN WHEN POWER IS REMOVED. WHEN POWER IS RESTORED, THE UNIT WILL RETURN TO ITS P

Page 6 - B) Status Requests

2.5.4 Frequency ChangesAt any time during the modification process, if you have made a mistake and do not wish to save the changes you have made, do

Page 7

2.5.5 Gain ChangesWhen you get to this menu note that the gain changes will be made as you make them but if you do not wish to save the changes you h

Page 8

2.5.5 Alarm IndicationsAn alarm condition for will occur if any local oscillator phase lock loop (PLL) comes out of lock. The Mute LED will light if

Page 9 - •••••••••••••••

CROSS TECHNOLOGIES, INC.6170 Shiloh RoadAlpharetta, Georgia 30005(770) 886-8005FAX (770) 886-7964Toll Free 888-900-5588WEB www.crosstechnologies.com E

Page 10 - G=+10 Ref = AUTO-I

INSTRUCTION MANUALMODEL 3016-2124 Downconverter TABLE OF CONTENTS PAGEWarranty 21.0 General 31.1 Equipment Description 31.2 Technica

Page 11 - SPARE FUSE

MODEL 3016-2124-Downconverter1.0 General1.1 Equipment DescriptionThe 3016-2124 Downconverter converts 21 to 24 GHz to 70 ± 18 MHz in 125 kHz steps (

Page 12

1.2 Technical Characteristics3016-2124- Manual_Rev.0 Page 4 8/02/12 Channel Characteristics Synthesizer Characteristics

Page 13 - G=+10 Ref=AUTO=I

1.3 Monitor and Control InterfaceA) Remote serial interfaceProtocol: RS-232C, 9600 baud rate, no parity, 8 data bits, 1 start bit, and 1 stop bit.

Page 14

B) Status Requests Table 1.1 lists the status requests for the 2016-03 and briefly describes them.* PLEASE NOTE: The two character {aa}(00-31) prefix,

Page 15

C) Commands - Table 1.1 lists the commands for the 3016-2124 and briefly describes them. After a command is sent the 3016-2124 sends a return “>” i

Page 16 - 2.5.5 Alarm Indications

1.4 Environmental Use InformationA. Rack-Mounting - To mount this equipment in a rack, please refer to the installation instructions located in the u

Page 17 - CROSS TECHNOLOGIES, INC

2.0 Installation2.1 MechanicalThe 3016-2124 consists of one RF/Controller PCB housed in a 1 RU (1 3/4 inch high) by 16 inch deep chassis. A switchin