Instruction Manual Model 3016-2124 DownconverterAugust 2012, Rev. 0MENUEXECUTEMODEL 3016CROSS TECHNOLOGIES INC.REMOTE POW
2.2 Rear Panel Input/Output Signals Figure 2.2 shows the input and output connectors on the rear panel.ACGNDJ1J10ANDMONITORCONTROL 5 4 3 2
2.4 Operation2.4.1 Installing and Operating the 3016-2124 Downconverter1. Connect a -50 dBm to -30 dBm signal to RF IN, J2 (Figure 2.2, page 10).2.
2.5 Menu Settings2.5.1 Functions This section describes operation of the front panel controls. There are three operator switches, the LCD displa
2.5.2 Power On SettingsNOTE: THE LAST STATUS OF A UNIT IS RETAINED EVEN WHEN POWER IS REMOVED. WHEN POWER IS RESTORED, THE UNIT WILL RETURN TO ITS P
2.5.4 Frequency ChangesAt any time during the modification process, if you have made a mistake and do not wish to save the changes you have made, do
2.5.5 Gain ChangesWhen you get to this menu note that the gain changes will be made as you make them but if you do not wish to save the changes you h
2.5.5 Alarm IndicationsAn alarm condition for will occur if any local oscillator phase lock loop (PLL) comes out of lock. The Mute LED will light if
CROSS TECHNOLOGIES, INC.6170 Shiloh RoadAlpharetta, Georgia 30005(770) 886-8005FAX (770) 886-7964Toll Free 888-900-5588WEB www.crosstechnologies.com E
INSTRUCTION MANUALMODEL 3016-2124 Downconverter TABLE OF CONTENTS PAGEWarranty 21.0 General 31.1 Equipment Description 31.2 Technica
MODEL 3016-2124-Downconverter1.0 General1.1 Equipment DescriptionThe 3016-2124 Downconverter converts 21 to 24 GHz to 70 ± 18 MHz in 125 kHz steps (
1.2 Technical Characteristics3016-2124- Manual_Rev.0 Page 4 8/02/12 Channel Characteristics Synthesizer Characteristics
1.3 Monitor and Control InterfaceA) Remote serial interfaceProtocol: RS-232C, 9600 baud rate, no parity, 8 data bits, 1 start bit, and 1 stop bit.
B) Status Requests Table 1.1 lists the status requests for the 2016-03 and briefly describes them.* PLEASE NOTE: The two character {aa}(00-31) prefix,
C) Commands - Table 1.1 lists the commands for the 3016-2124 and briefly describes them. After a command is sent the 3016-2124 sends a return “>” i
1.4 Environmental Use InformationA. Rack-Mounting - To mount this equipment in a rack, please refer to the installation instructions located in the u
2.0 Installation2.1 MechanicalThe 3016-2124 consists of one RF/Controller PCB housed in a 1 RU (1 3/4 inch high) by 16 inch deep chassis. A switchin
Comments to this Manuals